{"product_id":"jeio-tech-heating-cooling-chambers-pmv-series","title":"Jeio Tech | Heating and Cooling Chambers PMV Series","description":"\u003ch2\u003eJeio Tech | Heating and Cooling Chambers PMV Series | High Temperature Drying Oven with PID Control, Stainless Steel Chamber and Programmable LCD System\u003c\/h2\u003e\n\u003cp\u003eThe Jeio Tech High Temperature Drying Oven is designed for reliable heat treatment, drying, and laboratory testing applications.\u003c\/p\u003e\n\u003cp\u003eBuilt to meet DIN 12880 and IEC 60068-3-5 standards, this advanced laboratory oven delivers precise temperature control and dependable performance for research facilities, industrial laboratories, pharmaceutical environments, and quality control applications.\u003c\/p\u003e\n\u003cp\u003eAlto Med Supply proudly offers this high-quality Jeio Tech drying oven as part of our extensive selection of professional laboratory equipment from trusted brands.\u003c\/p\u003e\n\u003cp\u003eThis laboratory drying oven features advanced microprocessor PID control with automatic tuning and temperature calibration for accurate and stable heating performance.\u003c\/p\u003e\n\u003cp\u003eThe optimized insulation system improves energy efficiency while maintaining consistent chamber temperatures.\u003c\/p\u003e\n\u003cp\u003eHeat-resistant silicone door packing and a two-point door latch provide excellent airtight sealing to reduce heat loss during operation. \u003c\/p\u003e\n\u003cp\u003eEven at maximum operating temperature, the exterior surface remains safe with temperatures below 51°C according to DIN EN 563 standards.\u003c\/p\u003e\n\u003cp\u003eThe oven is built with a corrosion-resistant stainless steel inner chamber for durability, easy cleaning, and long-term use.\u003c\/p\u003e\n\u003cp\u003eIts space-efficient chamber design allows convenient loading of samples and includes two standard shelves, with optional heavy-duty shelves available for loads up to 40 kg. \u003c\/p\u003e\n\u003cp\u003eThe door structure is engineered for strength and reliability, ensuring stable operation even under demanding laboratory conditions.\u003c\/p\u003e\n\u003cp\u003eA user-friendly color touch LCD controller makes operation simple and efficient.\u003c\/p\u003e\n\u003cp\u003eUsers can easily monitor set temperatures and current operating conditions on the display, while graph mode allows quick viewing of operating progress and performance data.\u003c\/p\u003e\n\u003cp\u003eThe programmable control system supports automatic start and stop functions for unattended operation, multiple language options, and programmable patterns for advanced testing applications.\u003c\/p\u003e\n\u003cp\u003eOptional six-channel digital recording is available for monitoring temperature and operating parameters.\u003c\/p\u003e\n\u003cp\u003eThe programmable control system supports up to 100 programmable patterns, 999 pattern repeat cycles, 255 part repeat cycles, 100 segments per pattern, and a maximum of 2,000 programmable segments.\u003c\/p\u003e\n\u003cp\u003eEach segment can be programmed from 0 to 99 hours and 59 minutes, providing flexible control for complex laboratory heating and drying processes.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Treatment and Drying: \u003c\/strong\u003eIdeal for laboratory applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN and IEC Compliant:\u003c\/strong\u003e Meets industry testing standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Chamber: \u003c\/strong\u003eDurable and easy to clean.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouch LCD Controller: \u003c\/strong\u003eEasy operation and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Functions:\u003c\/strong\u003e Supports automated testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Protection: \u003c\/strong\u003eIncludes overheat, overload, and leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Connectivity:\u003c\/strong\u003e Supports RS-232 and optional RS-485.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export: \u003c\/strong\u003eEnables logging and reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Program Capacity: \u003c\/strong\u003eSupports up to 2,000 segments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePID Temperature Control:\u003c\/strong\u003e Accurate and stable heating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003ePMV-012\u003c\/th\u003e\n\u003cth\u003ePMV-025\u003c\/th\u003e\n\u003cth\u003ePMV-040\u003c\/th\u003e\n\u003cth\u003ePMV-070\u003c\/th\u003e\n\u003cth\u003ePMV-100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5°C To 100°C (-13°F To 212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd\u003e±0.2–0.3°C\u003c\/td\u003e\n\u003ctd\u003e±0.2–0.3°C\u003c\/td\u003e\n\u003ctd\u003e±0.2–0.3°C\u003c\/td\u003e\n\u003ctd\u003e±0.2–0.4°C\u003c\/td\u003e\n\u003ctd\u003e±0.2–0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Gradient\u003c\/td\u003e\n\u003ctd\u003e±0.2–1.0°C\u003c\/td\u003e\n\u003ctd\u003e±0.2–1.0°C\u003c\/td\u003e\n\u003ctd\u003e±0.3–0.8°C\u003c\/td\u003e\n\u003ctd\u003e±0.4–0.7°C\u003c\/td\u003e\n\u003ctd\u003e±0.3–0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"font-size: 0.875rem;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating and Cooling Performance (Minutes)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Change\u003c\/th\u003e\n\u003cth\u003ePMV-012\u003c\/th\u003e\n\u003cth\u003ePMV-025\u003c\/th\u003e\n\u003cth\u003ePMV-040\u003c\/th\u003e\n\u003cth\u003ePMV-070\u003c\/th\u003e\n\u003cth\u003ePMV-100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating: -5°C → 25°C\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating: 25°C → 60°C\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating: 25°C → 100°C\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating: -5°C → 100°C\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling: 25°C → -5°C\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling: 100°C → 25°C\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling: 100°C → -5°C\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"font-size: 0.875rem;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery Time After 30-Second Door Opening (Minutes)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003cth\u003ePMV-012\u003c\/th\u003e\n\u003cth\u003ePMV-025\u003c\/th\u003e\n\u003cth\u003ePMV-040\u003c\/th\u003e\n\u003cth\u003ePMV-070\u003c\/th\u003e\n\u003cth\u003ePMV-100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-5°C\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25°C\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003ctd\u003e7.0\u003c\/td\u003e\n\u003ctd\u003e7.0\u003c\/td\u003e\n\u003ctd\u003e7.0\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"font-size: 0.875rem;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical and Ordering Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eElectrical Requirement\u003c\/th\u003e\n\u003cth\u003eCatalog No.\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMV-012\u003c\/td\u003e\n\u003ctd\u003e380V, 50\/60Hz, 3Ph, 9.7A\u003c\/td\u003e\n\u003ctd\u003eAAHK4015K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMV-025\u003c\/td\u003e\n\u003ctd\u003e380V, 50\/60Hz, 3Ph, 13.2A\u003c\/td\u003e\n\u003ctd\u003eAAHK4025K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMV-040\u003c\/td\u003e\n\u003ctd\u003e230V, 60Hz, 1Ph, 15.5A\u003c\/td\u003e\n\u003ctd\u003eAAHK4031K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMV-070\u003c\/td\u003e\n\u003ctd\u003e230V, 60Hz, 1Ph, 21.7A\u003c\/td\u003e\n\u003ctd\u003eAAHK4041K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMV-100\u003c\/td\u003e\n\u003ctd\u003e380V, 50\/60Hz, 3Ph, 6.0A\u003c\/td\u003e\n\u003ctd\u003eAAHK4050K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e* Even though the max. segments per pattern are 100, the total available segments are up to 6000 not 10000, therefore arrangement of the number of segment and patterns will need to be done properly.\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003eUser manual for Jeio Tech Heating and Cooling Chambers PMV Series can be found \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5934\/4369\/files\/Jeio-Tech-Heating-Cooling-Chambers_PMV_-Guide.pdf?v=1779317272\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFree delivery (Contiguous United States Only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta\u003eDelivery ETA 3-7 business days\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003cspan\u003eWe also offer white glove engineer delivery with assembly and demonstration if required. Please \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/altomedsupply.com\/pages\/contact\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" target=\"_blank\"\u003e\u003cspan\u003econtact us\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta\u003eIf you require faster shipping or shipping anywhere other than the contiguous United States, please \u003ca rel=\"noopener\" href=\"https:\/\/altomedsupply.com\/pages\/contact\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" target=\"_blank\"\u003econtact us\u003c\/a\u003e for a shipping quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis product comes with a 2 year manufacturer's warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe warranty applies only to the original purchaser of a new product.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt does not cover:\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNormal wear and tear\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDamage due to misuse, alteration, tampering, negligence, accidents, lack of maintenance, unauthorized repair, or any other cause beyond the reasonable control of the manufacturer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIf you have any faults with your items, \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/altomedsupply.com\/pages\/contact\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" target=\"_blank\"\u003e\u003cspan\u003econtact us\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e and we'll help to resolve any issues.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eWarranty is void if the product is altered, misused, or repaired by unauthorized personnel. Damage from improper maintenance or unsuitable environmental conditions is also excluded.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant: Product Inspection Upon Delivery\u003c\/strong\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease inspect all items carefully for any damage that may have occurred during shipping immediately after unpacking and report within 24 hours of receiving the product.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eReturns\u003c\/h3\u003e\n\u003cp\u003eWe at Alto Med Supply are committed to ensuring you are delighted with every purchase. However, if you need to make a return, please reach out to us at \u003ca href=\"mailto:support@altomedsupply.com\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\"\u003esupport@altomedsupply.com\u003c\/a\u003e, and we'll guide you through the return process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHere are a few important points to note:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou have the right to return your order within 14 days of receiving your order. Beyond this period, we regret that returns cannot be accepted.\u003c\/li\u003e\n\u003cli\u003eProducts must be returned unused, and in their original packaging.\u003c\/li\u003e\n\u003cli\u003eUsed bathroom products cannot be returned due to hygiene reasons.\u003c\/li\u003e\n\u003cli\u003eReturn shipping costs and restocking fee may apply. You can contact us to find out what that will be at the time of purchase as this value can change.\u003c\/li\u003e\n\u003cli\u003eBespoke items cannot be returned unless damaged or faulty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more information, please refer to our \u003ca rel=\"noopener\" href=\"https:\/\/altomedsupply.com\/pages\/terms-and-conditions\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" target=\"_blank\"\u003eTerms and Conditions.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePlease view our full returns and refund policy \u003ca rel=\"noopener\" href=\"https:\/\/altomedsupply.com\/pages\/return-and-refund-policy\" title=\"Jeio Tech Heating and Cooling Chambers PMV Series\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e","brand":"Jeio Tech","offers":[{"title":"PMV012-230V60Hz","offer_id":48199682195697,"sku":"AAHK4012K","price":12340.0,"currency_code":"USD","in_stock":true},{"title":"PMV25-230V60Hz","offer_id":48199682228465,"sku":"AAHK4022K","price":13868.1,"currency_code":"USD","in_stock":true},{"title":"PMV40-230V50Hz","offer_id":48199682261233,"sku":"AAHK4031K","price":14791.5,"currency_code":"USD","in_stock":true},{"title":"PMV040-230V60Hz","offer_id":48199682294001,"sku":"AAHK4032K","price":14791.5,"currency_code":"USD","in_stock":true},{"title":"PMV070-230V50Hz","offer_id":48199682326769,"sku":"AAHK4041K","price":18118.0,"currency_code":"USD","in_stock":true},{"title":"PMV070-230V60Hz","offer_id":48199682359537,"sku":"AAHK4043K","price":18118.0,"currency_code":"USD","in_stock":true},{"title":"PMV100-380V60Hz","offer_id":48199682392305,"sku":"AAHK4058K","price":22213.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/5934\/4369\/files\/Jeio-Tech-Heating-and-Cooling-Chambers-PMVSeries-Main-Image.png?v=1780371260","url":"https:\/\/altomedsupply.com\/products\/jeio-tech-heating-cooling-chambers-pmv-series","provider":"Alto Med Supply","version":"1.0","type":"link"}