Accuris | SmartReader™ 96 Absorbance Plate Reader | Standalone ELISA Microplate Reader with Touchscreen, Wavelength Range 340–750 nm, and Optional Incubation
The Accuris SmartReader™ 96 Absorbance Plate Reader is a reliable, user-friendly solution for labs conducting absorbance measurements in standard 96-well plates.
Available in two models MR9600 and MR9600-T this versatile microplate reader offers advanced functionality in a compact, standalone design that does not require a separate computer or external software.
Ideal for ELISA and other endpoint or kinetic assays, the SmartReader™ 96 features a vibrant 7-inch color touchscreen and intuitive onboard software, allowing users to quickl
The filter-based optical system covers a wavelength range of 340–750 nm, and the reader comes equipped with four commonly used filters (405, 450, 492, and 630 nm).
The built-in filter wheel accommodates up to eight filters, with additional filters available for expanded assay compatibility.
With an absorbance detection range from 0.0 to 4.000 Abs, and an 8-channel vertical optical path for high precision and zero dispersion, this reader delivers accurate, reproducible results.
The integrated multi-speed plate shaker enhances mixing, while the MR9600-T model adds temperature-controlled incubation — maintaining temperatures from 5°C above ambient up to 50°C — ideal for temperature-sensitive assays.
Users can program the device directly through the touchscreen or connect a USB mouse for added flexibility.
The graphical plate layout interface enables quick labeling of well types, such as standards, blanks, controls, or unknowns.
Data is displayed instantly after a read, with built-in tools for kinetic analysis, curve fitting, and calculation of results.
For data management, the SmartReader™ 96 includes a USB port for exporting results as .csv files, making it easy to transfer to a PC or printer.
Additionally, newly released PC software supports remote programming and control from Windows computers.
For labs needing routine verification or performance checks, the optional MR9600-CAL Calibration Plate is available.
This accessory contains neutral density filters to assess absorbance accuracy, linearity, plate positioning, cross talk, and more.
Trusted in research settings and cited in peer-reviewed publications, the Accuris SmartReader™ 96 offers robust performance in a compact, easy-to-use package — available now from Alto Med Supply, your source for trusted laboratory equipment online.
Key Features
Standalone Operation: No external computer or software required — all functions are built into the unit.
7-Inch Color Touchscreen: Intuitive display for easy programming, setup, and viewing of results.
Wavelength Range 340–750 nm: Filter-based optical system with support for a wide range of assays.
Includes 4 Filters: Comes with 405, 450, 492, and 630 nm filters; 26 additional filters available separately.
Integrated Filter Wheel: Holds up to 8 filters at once, allowing for flexible and programmable wavelength selection.
Absorbance Range 0.0 to 4.000 Abs: Provides accurate, high-sensitivity absorbance readings.
8-Channel Optical Path: Vertical optical system with zero dispersion ensures precise measurements.
Built-In Plate Shaker: Multi-speed shaker supports consistent mixing during assays.
Temperature Control (MR9600-T Model): Incubation from 5°C above ambient up to 50°C for temperature-sensitive protocols.
Dual Wavelength Measurements: Supports two filters per assay for comparative or ratio-based readings.
USB Data Export: Save results as .csv files for easy transfer to a PC or printer.
Graphical Plate Layout Interface: Visual 96-well layout for quick setup and well labeling.
Multiple Well Designations: Label wells as standards, controls, blanks, or samples for streamlined workflows.
On-Screen Analysis: View results instantly, including calculations, curve fitting, and interpretations.
Optional Windows Software: PC software allows remote control and programming via Windows computers.
MR9600-CAL Calibration Plate: Optional accessory for routine performance checks and absorbance accuracy.
Cited in Scientific Research: Referenced in peer-reviewed publications, trusted by researchers.
Specifications
Specification
Details
Model
Accuris SmartReader 96
Control and Display
7 inch touch screen (800 x 480 pixels)
Light Source
Quartz-halogen lamp 6V/10W
Wavelength range
340-750nm (405, 450, 492 and 630 nm filters included)
Half-Bandwidth of filters
3-9nm
Readout Range
0~4.000 Abs
Linearity (405nm)
0~2.000 Abs <+1% 2~4.000 Abs <+2%
Precision
CV</= 0.2% (0-3) Abs CV</= 01.0% (3-4) Abs
Test Speed
<6 sec. for 96 well plate
Incubator (MR9600-T)
Temp control from ambient +5°C to 50°C
Shaking
3 modes: slow (3.5Hz), medium (4.7Hz), fast (7.0Hz)
User Interface
Integrated software, touch screen control
Storage
200 programs, 100,000 test records
Ports
USB ports for PC, printer, mouse and flash drive
Dimensions
29.5 x 44.0 x 22.5 cm 11.6 x 17 x 8.75 inches
Weight
10 kg
Warranty
2 Years
Product Manual
User manual for Benchmark Scientific Accuris SmartReader™ 96 Absorbance Plate Reader can be found here.
Video
Shipping
Free delivery (Contiguous United States Only)
Delivery ETA 3-7 business days
We also offer white glove engineer delivery with assembly and demonstration if required. Please contact us for a quote.
If you require faster shipping or shipping anywhere other than the contiguous United States, please contact us for a shipping quote.
Warranty
This product comes with a 2-year manufacturer's warranty.
Important Notes
The warranty applies only to the original purchaser of a new product.
It does not cover:
Normal wear and tear
Damage due to misuse, alteration, tampering, negligence, accidents, lack of maintenance, unauthorized repair, or any other cause beyond the reasonable control of the manufacturer.
If you have any faults with your items, contact us and we'll help to resolve any issues.
Conditions: Warranty is void if the product is altered, misused, or repaired by unauthorized personnel. Damage from improper maintenance or unsuitable environmental conditions is also excluded.
Important: Product Inspection Upon Delivery
Please inspect all items carefully for any damage that may have occurred during shipping immediately after unpacking and report within 24 hours of receiving the product.
Returns
We at Alto Med Supply are committed to ensuring you are delighted with every purchase. However, if you need to make a return, please reach out to us at support@altomedsupply.com, and we'll guide you through the return process.
Here are a few important points to note:
You have the right to return your order within 30 calendar days of receiving the goods. Beyond this period, we regret that returns cannot be accepted.
Products must be returned unused, and in their original packaging.
Return shipping costs and restocking fees apply. You can contact us to find out what that will be at the time of purchase as this value can change.
Bespoke items cannot be returned unless damaged or faulty.