Dynarex | DynaRest Airfloat 500 Medical Grade Alternating Pressure Air Mattress Replacement with Digital Pump and Low Air Loss Support
The Dynarex DynaRest Airfloat 500 Air Mattress with Digital Pump is a medical-grade alternating pressure mattress replacement system designed to enhance patient comfort and support pressure injury prevention.
Available from Alto Med Supply, this advanced air mattress features a digital pump with easy-to-use air pressure controls, allowing caregivers to customize firmness levels based on individual patient needs.
With a weight capacity of up to 350 lbs, it offers a reliable solution for a wide range of home care, long-term care, and clinical environments.
The Airfloat 500 combines low air loss and alternating pressure therapies in one system to help promote circulation and redistribute pressure.
Nineteen 8-inch air cells cycle automatically in alternating mode to reduce prolonged pressure on vulnerable areas, while static mode fully inflates all cells to provide a stable surface during patient repositioning or transfers.
An adjustable airflow dial further enhances comfort customization, and a built-in pillow function adds extra head and neck support.
Designed with caregiver safety and patient monitoring in mind, the digital pump includes a low-pressure indicator light and audible alarm to alert users of pressure loss.
The Dynarex DynaRest Airfloat 500 delivers dependable performance, ease of use, and therapeutic support, making it an effective pressure relief mattress replacement system for patients at risk of pressure wounds.
Key Features
-
Digital Air Pump with Pressure Controls: Allows easy adjustment of mattress firmness to meet individual patient comfort and support needs.
-
Alternating Pressure Mattress Replacement System: Designed to help redistribute pressure and support the treatment and prevention of pressure injuries.
-
Dual Therapy Design: Combines low air loss and alternating pressure therapies in one medical-grade air mattress system.
-
Two Operating Modes: Includes alternating cycle mode for pressure redistribution and static mode for stable support during patient transfers.
-
Static Mode for Safe Transfers: Fully inflates all air cells to reduce movement and lower the risk of caregiver or patient injury during repositioning.
-
19 High-Profile Air Cells: Features nineteen 8-inch pressure-cycling air cells for consistent support and enhanced comfort.
-
Adjustable Airflow Dial: Enables precise airflow control to match each patient’s comfort and clinical requirements.
-
Pillow Function: Built-in pillow feature provides additional head and neck support for improved comfort.
-
Low Pressure Alert System: Includes a low-pressure indicator light and audible alarm for added safety and monitoring.
-
350 lb Weight Capacity: Medical-grade design supports a wide range of patients in home care and clinical settings.
Specifications
| Specification |
Details |
| Power Supply |
120 V / 60 Hz |
| Power |
7 W |
| Fuse Rating |
1A / 250 V |
| Pressure |
30 mmHg - 60 mmHg |
| Dimensions (Pump Control Unit) |
11″ (W) × 9″ (L) × 3.5″ (H) |
| Cycle |
10 mins |
| Weight (Pump Control Unit) |
7 lb. |
| Environment Temperature |
Operation: +10˚C / +40˚C Storage: -15˚C / +50˚C Shipping: -15˚C / +70˚C |
| Environment Humidity |
Operation: 10%~85% Storage: 10%~85% non-condensing Shipping: 10%~85% non-condensing |
| Atmospheric Pressure |
Operation: 700-1013.25 hPa |
| Dimensions (Mattress) |
80″ (L) × 35″ (W) × 8″ (H) |
| Cell Height (inflated) |
8″ |
| Air Cell Material |
Nylon/PVC |
| Cover Material |
Nylon/PU |
| Elements Number |
19 cells |
| Max Weight |
350 lb. |
| Weight (Mattress) |
17.6 lb. |
Product Manual
The User Manual for Dynarex DynaRest Airfloat 500 Air Mattress with Digital Pump can be found here
Warranty
This product includes a 1 year limited warranty on the pump and a 90-day warranty on the mattress.
Important Notes
The warranty applies only to the original purchaser of a new product.
It does not cover:
- Normal wear and tear
- Damage due to misuse, alteration, tampering, negligence, accidents, lack of maintenance, unauthorized repair, or any other cause beyond the reasonable control of the manufacturer.
If you have any faults with your items, contact us and we'll help to resolve any issues.
Conditions: Warranty is void if the product is altered, misused, or repaired by unauthorized personnel. Damage from improper maintenance or unsuitable environmental conditions is also excluded.
Important: Product Inspection Upon Delivery
Please inspect all items carefully for any damage that may have occurred during shipping immediately after unpacking and report within 24 hours of receiving the product.
Returns
We at Alto Med Supply are committed to ensuring you are delighted with every purchase. However, if you need to make a return, please reach out to us at support@altomedsupply.com, and we'll guide you through the return process.
Here are a few important points to note:
- You have the right to return your order within 14 calendar days of receiving the goods. Beyond this period, we regret that returns cannot be accepted.
- Products must be returned unused, and in their original packaging.
-
Return shipping costs and restocking fee apply. Please contact us at the time of order to check the return shipping costs and restocking fee as this value can change.
- Opened bathroom products cannot be returned due to hygiene reasons.
- Bespoke items cannot be returned unless damaged or faulty.
For more information, please refer to our Terms and Conditions.
Please view our full returns and refund policy here.